Substation transformer
Cold Rolled Grain Oriented Silicon Steel in Power Transformer
Cold Rolled Distribution Transformer Silicon Steel
Cold Rolled Oriented Silicon Steel in Power Transformer
Grain Oriented Electrical Steel for Transformer
Cold Rolled Grain Oriented Silicon Steel in Power Transformer
Cold Rolled Distribution Transformer Silicon Steel
Cold Rolled Oriented Silicon Steel in Power Transformer
Grain Oriented Electrical Steel for Transformer
60-second manual response
24 hours free plan
Production quality checks at every level

Step Down Three Phase Pad Mounted Transformer

Pad-mounted transformers are made in power ratings from around 75 to around 5000 kVA and often include built-in fuses and switches. Primary power cables are connected with elbow connectors, which can be operated when energized using a hot stick and allows for flexibility in repair and maintenance.
Application :
Power, Electric
Core:
Core-type Transformer
Product Details
Parameter
Advantage
Service
Message
application Details
Non-Oriented Electrical Steel for Transformer
Oriented Silicon Steel in Power Transformer Product Introduction
The rated power of the transformer is 225 kVA, with the primary voltage 24.94GRDY/14.4 kV to secondary voltage 0.48GrdY/0.277 kV. The connection group is YNyn0, and there are 5 taps ABCDE to adjust the voltage at the primary side, where can output 5 different voltages as wanted.
The 225 kVA Pad mounted transformer is welled design with 98.94% efficiency and our advanced manufacturing process, which may satisfy various voltage requirements.

GNEE ensure that every of our delivered units has undergone full acceptance testing. Our oil immersed power transformer is designed in accordance with CSA, IEEE, ANSI and other major international standards.

Non-Oriented Silicon Steel in Power Transformer Scope of Supply
Product: Pad mounted transformer

Standard

CSA

IEEE

Rated Power

Up to 3000 KVA

Up to 5000 KVA

Primary Voltage:

Up to 34.5 KV

Up to 34.5 KV

technical parameter
Silicon Steel Transformer

Technical Specification
225 kVA Pad mounted transformer specification and data sheet

Model

225 kVA/24.94/0.48 kV

Type

Oil Type Pad Mounted Transformer

Standard

CSA C227.4:21

Rated Power

225 kVA

Frequency

60 HZ

Phase

Three

Cooling Type

ONAN

Primary Voltage

24.94GRDY/14.4 kV

Secondary Voltage

0.48GrdY/0.277 kV

Winding Material

ALUMINUM

Vector Group

YNyn0

Impedance

4%

Tap Changer

NLTC

Tapping Range

±2*2.5% @ Primary Side

No Load Loss

0.62KW

On Load Loss

2.59KW

Accessories

Standard Configuration

Remarks

N/A

General Arrangement Drawing

225 kVA Pad mounted transformer dimensions and weight details




our Service
Gnee Silicon Steel Provide
One-stop Service
Message
Get In tTouch With Us Quickly
Related Products
Grain Oriented Silicon Steel Coil
Related Products
Application:Power, Electronic, Instrument, Lighting, Rectifier, Audio, Power Utility
Core:Core-type Transformer
Type: Cast Resin Dry Type Transformer
Phase: Three phases
Application : Power, Electric
Core : Core-type Transformer